Laboratory Assessment of the Elemental Composition of Dental Implant Surfaces Based on X-Ray Spectral Analysis with Mapping
Dental implantation is a current solution of dental surgery problem related to alveolar bone defects occurring after tooth extraction. The effectiveness of dental implant integration is the full osseointegration within the jawbone provides by the cleanliness of the implant surface. The research purpose of the study was a comparative laboratory assessment of the elemental chemical composition of the dental implants surface using X-ray spectral analysis in order to improve the efficiency of osseointegration. Materials and Methods. The chemical composition of the dental implants surface was studied using X-ray spectral analysis. Results and Discussion. The results obtained through high-tech methods allow substantiating the advantage of a dental implant without contamination surface areas in terms of its biocompatibility and long-term stability.
Azarova N.S., Kharitonov I.D., Agapov B.L., Stepanov I.V., Kvashnin D.V., Antonyan A.B. 2026. Laboratory Assessment of the Elemental Composition of Dental Implant Surfaces Based on X-Ray Spectral Analysis with Mapping. Challenges in Modern Medicine, 49(2): 199–207 (in Russian). DOI: 10.52575/2687-0940-2026-49-2-199-207. EDN: IHUWPZ




While nobody left any comments to this publication.
You can be first.
Список литературы
Азарова Н.С. Харитонов И.Д. 2025. Лабораторная оценка морфологических параметров остеоинтеграции отечественных дентальных имплантатов. Прикладные информационные аспекты медицины, 28(1): 4–9. doi:10.18499/2070-9277-2025-28-1-4-9
Азарова Н.С. Харитонов И.Д. 2025. Сравнительный анализ морфохимических параметров дентальных имплантатов по данным сканирующей электронной микроскопии и рентгеноспектрального анализа. Институт стоматологии, 4(109): 134–136.
Моисеева Н.С. 2022. Клинико-лабораторный анализ элементного состава челюстной костной ткани и остеопластических материалов по данным рентгеноспектрального микроанализа / Н.С. Моисеева // Вестник новых медицинских технологий, 29(1): 59–62. doi: 10.24412/1609-2163-2022-1-59-62
Перемультер М.Н. 2023. Влияние плотности костных тканей на напряженно-деформированное состояние вблизи дентальных имплантатов. Вестник Самарского государственного технического университета. Физико-математические науки. 27(1): 189–201. doi: 10.14498/vsgtu1976
Рыжова И.П., Погосян Н.М., Гонтарев С.Н., Чуев И.С., Гонтарева И.С., Новожилова М.С., Денисова В.Ю. 2022. Роль непосредственного протезирования в процессе хирургической подготовки альвеолярной костной ткани к имплантации. Вестник новых медицинских технологий. 29(4): 57–61. doi: 10.24412/1609-2163-2022-4-57-61
Фролов А.М., Погосян Н.М., Рыжова И.П., Денисова В.Ю. 2025. Клинический случай консервативной подготовки альвеолярной костной ткани перед имплантацией во фронтальном отделе. Актуальные проблемы медицины, 48(1): 59–68. doi: 10.52575/2687-0940-2025-48-1-59-68
Шакало Д.Н., Гончаров А.В., Иванюга Т.В. 2025. Основы статистического анализа. СпБ., Лань, 92.
Callejas J.A., Gil J., Brizuela A., Pérez R.A., Bosch B.M. 2022. Effect of the Size of Titanium Particles Released from Dental Implants on Immunological Response. Int. J. Mol. Sci. 30; 23(13): 7333. doi: 10.3390/ijms23137333. PMID: 35806339; PMCID: PMC9266706
Fonseca D., Pons R., de Tapia B., Monje A., Nart J., Aparicio C., Gil J. 2025. Effect Of Electrolytic Cleaning on Mechanical Properties for Titanium Dental Implants with Surface Contamination. Int. J. Oral Maxillofac Implants, 40(6): 725–734. doi: 10.11607/jomi.11082. PMID: 40512528
Jordan A., Smojver I., Budimir A., Gabrić D., Vuletić M. 2024. Evaluation of Different Procedures for Titanium Dental Implant Surface Decontamination-In Vitro Study. Bioengineering (Basel), 11(4): 326. doi: 10.3390/bioengineering11040326. PMID: 38671748; PMCID: PMC11048723
Messous R., Henriques B., Bousbaa H., Silva F.S., Teughels W., Souza J.C.M. 2021. Cytotoxic Effects of Submicron- and Nano-Scale Titanium Debris Released from Dental Implants: An Integrative Review. Clinical Oral Investigations. 25(4): 1627–1640. doi: 10.1007/s00784-021-03785-z. Epub 2021 Feb 22. PMID: 33616805
Sharon E., Pietrokovski Y., Engel I., Assali R., Houri-Haddad Y., Beyth N. 2023. Biocompatibility, Surface Morphology, and Bacterial Load of Dental Implant Abutments following Decontamination Protocols: An In-Vitro Study. Materials (Basel). 16 (11): 4080. doi: 10.3390/ma16114080. PMID: 37297212; PMCID: PMC10254387
Wu X., Cai C., Gil J., Jantz E., Al Sakka Y., Padial-Molina M., Suárez-López Del Amo F. 2022. Characteristics of Particles and Debris Released after Implantoplasty: A Comparative Study. Materials (Basel). 14; 15(2): 602. doi: 10.3390/ma15020602. PMID: 35057319; PMCID: PMC8779414
References
Azarova N.S., Kharitonov I.D. 2025. Clinical and Laboratory Assessment of Dental Implants Morphology to improve the Efficiency of Osseointegration. Applied Information Aspects of Medicine. 28(1): 4–9 (in Russian). doi:10.18499/2070-9277-2025-28-1-4-9
Azarova N.S., Kharitonov I.D. 2025. Comparative Analysis of the Morphochemical Parameters of Dental Implants Based on Scanning Electron Microscopy and X-ray Spectral Analysis. The Dental Institute, 4(109): 134–136 (in Russian).
Moiseeva N.S. 2022. Clinical and Laboratory Analysis of the Elemental Composition of the Jaw Bone and Osteoplastic Materials According to X-ray Spectral Microanalysis / N.S. Moiseeva // Journal of New Medical Technologies, 29(1): 59–62 (in Russian). doi: 10.24412/1609-2163-2022-1-59-62
Perelmuter M.N. 2023. The Effect of Bone Tissue Density on the Stress-Strain State near Dental Implants. Journal of Samara State Technical University, Ser. Physical and Mathematical Sciences. 27(1): 189–201 (in Russian). doi: 10.14498/vsgtu1976
Ryzhova I.P., Pogosyan N.M., Gontarev S.N., Chuev I.S., Gontareva I.S., Novozhilova M.S., Denisova V.Yu. 2022. The Role of Direct Prosthetics in the Process of Bone Augmentation for Implantation. Journal of New Medical Technologies. 29(4): 57–61 (in Russian). doi: 10.24412/1609-2163-2022-4-57-61
Frolov A.M., Pogosian N.M., Ryzhova I.P., Denisova V.Yu. 2025. Clinical Case of Conservative Alveolar Bone Augmentation before Implantation in Esthetic Area. Challenges in Modern Medicine, 48(1): 59–68 (in Russian). DOI: 10.52575/2687-0940-2025-48-1-59-68
Shakalo D.N., Goncharov A.V., Ivanyuga T.V. 2025. Fundamentals of Statistical Analysis. SPb., Lan, 92 (in Russian).
Callejas J.A., Gil J., Brizuela A., Pérez R.A., Bosch B.M. 2022. Effect of the Size of Titanium Particles Released from Dental Implants on Immunological Response. Int. J. Mol. Sci. 30; 23(13): 7333. doi: 10.3390/ijms23137333. PMID: 35806339; PMCID: PMC9266706
Fonseca D., Pons R., de Tapia B., Monje A., Nart J., Aparicio C., Gil J. 2025. Effect Of Electrolytic Cleaning on Mechanical Properties for Titanium Dental Implants with Surface Contamination. Int. J. Oral Maxillofac Implants, 40(6): 725–734. doi: 10.11607/jomi.11082. PMID: 40512528
Jordan A., Smojver I., Budimir A., Gabrić D., Vuletić M. 2024. Evaluation of Different Procedures for Titanium Dental Implant Surface Decontamination-In Vitro Study. Bioengineering (Basel), 11(4): 326. doi: 10.3390/bioengineering11040326. PMID: 38671748; PMCID: PMC11048723
Messous R., Henriques B., Bousbaa H., Silva F.S., Teughels W., Souza J.C.M. 2021. Cytotoxic Effects of Submicron- and Nano-Scale Titanium Debris Released from Dental Implants: An Integrative Review. Clinical Oral Investigations. 25(4): 1627–1640. doi: 10.1007/s00784-021-03785-z. Epub 2021 Feb 22. PMID: 33616805
Sharon E., Pietrokovski Y., Engel I., Assali R., Houri-Haddad Y., Beyth N. 2023. Biocompatibility, Surface Morphology, and Bacterial Load of Dental Implant Abutments following Decontamination Protocols: An In-Vitro Study. Materials (Basel). 16 (11): 4080. doi: 10.3390/ma16114080. PMID: 37297212; PMCID: PMC10254387
Wu X., Cai C., Gil J., Jantz E., Al Sakka Y., Padial-Molina M., Suárez-López Del Amo F. 2022. Characteristics of Particles and Debris Released after Implantoplasty: A Comparative Study. Materials (Basel). 14; 15(2): 602. doi: 10.3390/ma15020602. PMID: 35057319; PMCID: PMC8779414