<?xml version='1.0' encoding='utf-8'?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.2 20190208//EN" "http://jats.nlm.nih.gov/publishing/1.2/JATS-journalpublishing1.dtd">
<article article-type="research-article" dtd-version="1.2" xml:lang="ru" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><front><journal-meta><journal-id journal-id-type="issn">2687-0940</journal-id><journal-title-group><journal-title>Актуальные проблемы медицины</journal-title></journal-title-group><issn pub-type="epub">2687-0940</issn></journal-meta><article-meta><article-id pub-id-type="doi">10.18413/2687-0940-2020-43-1-113-122</article-id><article-id pub-id-type="publisher-id">14</article-id><article-categories><subj-group subj-group-type="heading"><subject>ХИРУРГИЯ</subject></subj-group></article-categories><title-group><article-title>СРАВНЕНИЕ ЗАЯВЛЕННЫХ ПРОИЗВОДИТЕЛЕМ ТЕХНИЧЕСКИХ ХАРАКТЕРИСТИК С ПОСЛЕОПЕРАЦИОННЫМИ РЕЗУЛЬТАТАМИ У ЧЕТЫРЕХ ВИДОВ КАРКАСНЫХ БИОПРОТЕЗОВ В АОРТАЛЬНОЙ ПОЗИЦИИ</article-title><trans-title-group xml:lang="en"><trans-title>COMPARISON OF THE MANUFACTURER&amp;#39;S TECHNICAL SPECIFICATIONS WITH POSTOPERATIVE RESULTS IN FOUR TYPES OF STENTED BIOPROSTHESES IN THE AORTIC POSITION</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author"><name-alternatives><name xml:lang="ru"><surname>Сазоненков</surname><given-names>Максим Александрович</given-names></name><name xml:lang="en"><surname>Sazonenkov</surname><given-names>Maksim A.</given-names></name></name-alternatives><email>sazonenkov@mail.ru</email></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="ru"><surname>Исматов</surname><given-names>Хушбахтджон Хасанович</given-names></name><name xml:lang="en"><surname>Ismatov</surname><given-names>Hushbahtdzhon H.</given-names></name></name-alternatives></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="ru"><surname>Присяжнюк</surname><given-names>Евгений Игоревич</given-names></name><name xml:lang="en"><surname>Prisyazhnyuk</surname><given-names>Evgeny I.</given-names></name></name-alternatives></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="ru"><surname>Селюкова</surname><given-names>Е. И.</given-names></name><name xml:lang="en"><surname>Selyukova</surname><given-names>E. I.</given-names></name></name-alternatives></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="ru"><surname>Гречишкина</surname><given-names>Ю. К.</given-names></name><name xml:lang="en"><surname>Grechishkina</surname><given-names>Yu. K.</given-names></name></name-alternatives></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="ru"><surname>Коваленко</surname><given-names>Игорь Борисович</given-names></name><name xml:lang="en"><surname>Kovalenko</surname><given-names>Igor B.</given-names></name></name-alternatives></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="ru"><surname>Куликовский</surname><given-names>В. Ф.</given-names></name><name xml:lang="en"><surname>Kulikovsky</surname><given-names>V. F.</given-names></name></name-alternatives></contrib></contrib-group><pub-date pub-type="epub"><year>2020</year></pub-date><volume>43</volume><issue>1</issue><fpage>0</fpage><lpage>0</lpage><self-uri content-type="pdf" xlink:href="/media/journal-medicine/2020/1/113-122.pdf" /><abstract xml:lang="ru"><p>Вопрос оптимального выбора биопротеза для аортальной позиции еще не решен. Мы использовали каркасные биопротезы четырех производителей для протезирования аортального клапана в старшей возрастной группе. Задачей исследования было проанализировать технические характеристики использованных биопротезов и сравнить их с собственными и доступными в литературе клиническими результатами. Исследование носит характер ретроспективного нерандомизированного. В кардиохирургическом отделении Белгородской областной клинической больницы Святителя Иоасафа с 1.01.2007 по 1.06.2018 в аортальную позицию было имплантировано 169 биологических протезов трех типоразмеров: 21 мм (n=74), 23 мм (n=66), 25 мм (n=29). Использовались каркасные биопротезы 4 производителей: Carpentier-Edwards PERIMOUNT (Edwards, США), Aspire (Vascutek, США), Hancock-2 (Medtroniс, США), ЮниЛайн (ЗАО &amp;laquo;Неокор&amp;raquo;, Россия). Технические характеристики биопротезов были взяты из официальных источников производителей. Произведено сравнение пикового, среднего градиентов, ударного объема левого желудочка у использованных типов протезов. Наилучшие показатели кровотока по выбранным трем параметрам имелись у каркасного биопротеза ЮниЛайн во всех трех типоразмерах. Уступает по всем показателям каркасный ксеноаортальный биопротез Hancock-2. По морфометрическим данным: внутренний диаметр (ВД), наружный диаметр (НД), соотношение внутреннего и наружного диаметров также суммарно лучшие результаты у биопротеза &amp;laquo;Неокор&amp;raquo; ЮниЛайн. Из исследованных четырех типов биопротезов ЮниЛайн показал лучшие потоковые характеристики. Его соотношение внутреннего и наружного диаметров является наиболее оптимальным. Что предполагает большую долговременность данного биопротеза. А также лучшие систолическую и диастолическую функции левого желудочка и более полный регресс его гипертрофии. Совместно с мягким каркасом он является наиболее удобным для хирургической имплантации.</p></abstract><trans-abstract xml:lang="en"><p>The problem of the best bioprosthesis type for aortic valve substitute is unresolved. We used bioprostheses from four manufacturers for patients in older age group. The aim of the study was to analyze technical characteristics of the valves, compare hemodynamics between four valve types in 21, 23, 25 sizes in our and literature data. The research was retrospective and unrandomised. During the period 1.01.2007&amp;ndash;1.06.2018 in the district of cardiosurgery of Belgorod regional Hospital 169 bioprostheses were implanted in aortic position. 21 mm size valves were used in 74 cases, 23 mm size in 66 cases, 25 mm in 29 cases. Stented bioprostheses of four manufacturers were used: Carpentier-Edwards PERIMOUNT (Edwards, USA), Aspire (Vascutek, USA), Hancock-2 (Medtroniс, USA), UniLine (NeoCor, Russia). Technical characteristics of the valves were obtained from official sources of manufacturers. The evaluated parameter were: peak and mean gradient, stroke volume. Comparison of three hemodynamic parameters in early postoperative period revealed best hydrodynamic results with UniLine (NeoCor) valve. The Hancock-2 stented valve conceded all other prostheses. According to technical characteristics: internal diameter, external diameter and their interrelationship the best was the UniLine (NeoCor) valve. Among the four investigated valves the UniLine (NeoCor) valve showed most effective hemodynamics and morphometry. Thus it proposes better systolic and diastolic left ventricle function, more complete hypertrophy regress. In combination with flexible stent this valve is preferable for surgical implantation.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>каркасные биопротезы</kwd><kwd>аортальная позиция</kwd><kwd>сравнительная гемодинамика</kwd></kwd-group><kwd-group xml:lang="en"><kwd>stented bioprostheses</kwd><kwd>aortic position</kwd><kwd>hemodynamics comparison</kwd></kwd-group></article-meta></front><back><ref-list><title>Список литературы</title><ref id="B1"><mixed-citation>1. Бокерия Л.А., Скопин И.И., Сазоненков М.А., Тумаев Е.Н. 2008. К вопросу анатомии корня аорты. Соотношение диаметров аортального кольца и синотубулярного соединения в норме у взрослых. Идеальная геометрическая модель корня аорты. Бюллетень НЦССХ им. А.Н. Бакулева РАМН. 9 (4): 77&amp;ndash;85.</mixed-citation></ref><ref id="B2"><mixed-citation>2. Информация производителя. ЗАО &amp;laquo;НеоКор&amp;raquo; 1978&amp;ndash;2020, https://neocor.ru/aortalnyy-klapan-3.</mixed-citation></ref><ref id="B3"><mixed-citation>3. Караськов А.М., Железнев С.И., Рогулина Н.В., Сапегин А.В., Одаренко Ю.Н., Левадин Ю.В., Рутковская Н.В., Барбараш Л.С. 2017. Отечественный биологический протез нового поколения &amp;laquo;Юнилайн&amp;raquo; в хирургии митрального порока: первый опыт / Грудная и сердечно-сосудистая хирургия. 59 (2): 98&amp;ndash;104.</mixed-citation></ref><ref id="B4"><mixed-citation>4. Клышников К.Ю., Овчаренко Е.А., Щеглова Н.А., Барбараш Л.С. 2017. Функциональные характеристики биопротезов &amp;laquo;Юни-Лайн&amp;raquo;. Комплексные проблемы сердечно-сосудистых заболеваний. 3: 6&amp;ndash;12. https://doi.org/10.17802/2306-1278-2017-6-3-6-12.</mixed-citation></ref><ref id="B5"><mixed-citation>5. Рогулина Н.В., Сизова И.Н., Горбунова Е.В. 2013. Левые отделы сердца после коррекции митрального порока протезами: &amp;laquo;МИКС&amp;raquo;, &amp;laquo;МЕДИНЖ2&amp;raquo;, &amp;laquo;КемКор&amp;raquo;, &amp;laquo;Перикор&amp;raquo; Российский кардиологический журнал. 5 (103): 35&amp;ndash;39.</mixed-citation></ref><ref id="B6"><mixed-citation>6. Сазоненков М.А., Исматов Х.Х., Поповичев С.В., Присяжнюк Е.И., Селюкова Е.И., Гречишкина Ю.К., Коваленко И.Б., Куликовский В.Ф. 2020. Сравнительная оценка непосредственных результатов протезирования аортального клапана каркасными биологическими протезами: СЕ Perimount, Aspire, Hancock-2, Юнилайн. Комплексные проблемы сердечно-сосудистых заболеваний. 9(1): (в печати).</mixed-citation></ref><ref id="B7"><mixed-citation>7. Федоров С.В., Чигинев В.А., Журко С.А., Гамзаев А.Б., Медведев А.П. 2016. Клинические и гемодинамические результаты использования различных моделей биологических протезов для коррекции сенильных пороков аортального клапана. СТМ. 8(4): 292&amp;ndash;296.</mixed-citation></ref><ref id="B8"><mixed-citation>8. Чигинев В.А., Есин С.Г., Журко С.А. 2014. Непосредственные результаты коррекции различных клапанных пороков биопротезам Vascutek Aspire у пациентов пожилого и старческого возраста. Медицинский Альманах. 2 (32): 157&amp;ndash;160.</mixed-citation></ref><ref id="B9"><mixed-citation>9. Burk J., Blanke P., Stankovic Z., Barker A., Russe M., Geiger J., Frydrychowicz A., Langer M., Markl M. 2012. Evaluation of 3D blood flow patterns and wall shear stress in the normal and dilated thoracic aorta using flow-sensitive 4D CMR. J. Cardiovasc. Magn. Reson. 14(1): 84.</mixed-citation></ref><ref id="B10"><mixed-citation>10. Ji Hoon You, Dong Seop Jeong, Kiick Sung, Wook Sung Kim, K.C. Carriere, Young Tak Lee, Pyo Won Park. 2016. Aortic Valve Replacement With Carpentier-Edvards: Hemodynamic Outcomes for the 19th Valve. Ann Thorac Surg. 101: 2209&amp;ndash;16.</mixed-citation></ref><ref id="B11"><mixed-citation>11. Marquez S., Hon R.T., Yoganathan A.P. 2001. Comparative hydrodynamic evaluation of bioprosthetic heart valves. J. Heart. Valve. Dis. 10(6): 802&amp;ndash;11.</mixed-citation></ref><ref id="B12"><mixed-citation>12. Theodore Long, Becky M. Lopez, Christopher Berberian, Mark J. Cunningham, Vaughn A. Starnes and Robbin G. Cohen. 2014. Exercise Hemodynamics and Quality of Life after Aortic Valve Replacement for Aortic Stenosis in the Elderly Using the Hancock II Bioprosthesis.Cardiology Research and Practice Volume. Article ID 151282, 5 pages, http://dx.doi.org/10.1155/2014/151282.</mixed-citation></ref><ref id="B13"><mixed-citation>13. Vinayak Bapat, Rizwan Attia, Simon Redwood, Jane Hancock, Karen Wilson, Christopher Young and Martyn Thomas. 2012. Use of transcatheter heart valves for a valve-in-valve implantation in patients with degenerated aortic bioprosthesis: Technical considerations and results.The Journal of Thoracic and Cardiovascular Surgery. 144(6): 1372&amp;ndash;80.</mixed-citation></ref><ref id="B14"><mixed-citation>14. Weigang E., Kari F.A., Beyersdorf F., Luehr M., Etz C.D., Frydrychowicz A., Harloff A., Markl M. 2008. Flow-sensitive four-dimensional magnetic resonance imaging: flow patterns in ascending aortic aneurysms. Eur. J. Cardiothorac. Surg. 34(1): 11&amp;ndash;6.</mixed-citation></ref><ref id="B15"><mixed-citation>15. Company official information. Medtronic plc. 1949&amp;ndash;2020, https://www.medtronic.com</mixed-citation></ref><ref id="B16"><mixed-citation>16. Company official information. Edwards Life sciences. 1956&amp;ndash;2020, https://www.edwards.com</mixed-citation></ref></ref-list></back></article>